set the data for port.
port bit-pattern:
Peripheral ports PA, PB and Control ports lines CA2, CB2:
- 0 low level
- 1 high level
So for example, when port is PB and bit-pattern is 0b00001111, lines PB0..PB3 are set high (1) and lines PB4..PB7 are set low (0).
A bit-pattern of 0b10 for CB (or CA), indicates that CB2 is set high (CB2 is at bit-position 1). CA1 and CB1 are input-only.
See also RB8506 PPORT Get Port Data.

|
|
handle is a handle to the Parallel Interface. |
|
|
error in (no error) The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs. The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed. |
|
|
status The status boolean is either TRUE (X) for an error, or FALSE (checkmark) for no error or a warning. The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed. |
|
|
code The code input identifies the error or warning. The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed. |
|
|
source The source string describes the origin of the error or warning. The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed. |
|
|
port (PA) peripheral port, PA, PB, or control port CA , CB. |
|
|
data (0) port data bit-pattern. |
|
|
error out The error out cluster passes error or warning information out of a VI to be used by other VIs. The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed. |
|
|
status The status boolean is either TRUE (X) for an error, or FALSE (checkmark) for no error or a warning. The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed. |
|
|
code The code numeric identifies the error or warning. The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed. |
|
|
source The source string describes the origin of the error or warning. The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed. |
|
|
dup handle is a duplicate handle to the Parallel Interface. |
|
|
dup port peripheral port, PA, PB, or control port CA , CB. |
Functions | |
| int | RB8506_PPORT_Set_Port_Data () |
| dummy C-definition to enable doxygen to generate proper index entry for the click here for more help in LabVIEW. | |
|
|
The VI is mentioned here as a C-function so that the proper index entry is generated for the click here for more help in LabVIEW. |